Customization: | Available |
---|---|
After-sales Service: | Warranty |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description
The cable fault tester adopts an industrial-grade 10.1-inch touch-integrated computer, a simple operating software interface, industrial-grade integrated circuits and devices, and a built-in large-capacity lithium-ion battery, which is stable, reliable, and easy to use.
This cable fault tester is a special instrument for measuring and analyzing the status and fault distance of power cables. This cable fault tester uses a combination of modern electronic technology and computer technology to achieve signal filtering, acquisition, data processing, graphic display, and graphic analysis. Cable speed measurement, cable length test, cable fault distance test.
This cable fault tester is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Network failure. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites", "DL/T 849.1-2019 General technical conditions for special testers for power equipment Part 1: Cable fault flash tester", "JJF1042-2020" "Calibration Specifications for Cable Fault Testers" standard requirements.
Work mode: TDR(low voltage pulse), High voltage flashover( ICE(Impulse current)/Decay)
Features
• 10.1-inch full-color TFT touch display;
• Embedded system, safe, stable and simple display and operation mode;
• With the function of testing cable wave speed, cable length and fault distance;
• Fully automatic continuous sampling, waveform capture at all times, timely and accurate.
• Equipped with automatic test range setting, automatic waveform analysis and display of test distance.
• Full English menu, two operation methods of touch and coded buttons, simple, fast and reliable.
• Equipped with testing technology of low-voltage pulse method, high-voltage flashover method, the waveform display is smooth and easy to interpret.
• The instrument has powerful data processing capabilities, making it convenient for users to manage and archive waveform files.
• Has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument in the order specified by Chinese naming for recall and observation at any time; it can store more than 8,000 records of low-voltage pulses and high-voltage flashover waveforms, and multiple pulses More than 250 waveform records can be recorded, and waveform files can be imported into computer software for management and analysis using USB communication.
• Ultra-high brightness, LED backlight brightness reaches 280nit, resolution 1024*600, convenient for environments exposed to direct sunlight in operation.
Technical specification
Sampling frequency | 80MHz |
Low voltage pulse amplitude | 100V±15% |
Ranging range | ≥65km |
Test range | 300m/1km/5km/25km/65km |
Pulse width | 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS |
Minimum resolution | 0.1m |
Test blind area | ≤20m |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
Power supply mode | charging AC110V~240V, 50Hz/60Hz |
Volume and weight | L358mm×W284mm×H168mm-4.7kg |
Working conditions | Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg |
Packing list
Description
The XHHV515-8L High voltage pulse generator is a tie-rod portable integrated device, which is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry.
Panel introductionPanel function description
1. Safety ground: The ground of the instrument shell must be reliably connected to the
ground in order to prevent the instrument shell from being electrified or electric shock to
personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to
prevent high-voltage leakage and discharge. Poor contact may cause failure to boost
the voltage, high voltage breakdown of the internal components of the instrument, and
safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a
high voltage and must be grounded reliably. It is used for sampling when the waveform
is sampled under the high-voltage flashover state of the cable fault tester. (WithoutHigh voltage surge generator
high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge
manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage
output is in the zero position. When the light is on, the start button is valid. If the start
button light is not on after turning on the power switch, turn the voltage adjustment knob
counterclockwise until the light is on. When the button light is on, press this button to
start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs,
press this button to cut off the high-voltage output, the high-voltage light goes out, and
the internal discharge ball stops working. When the stop key is on, it means there is
high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current
protection function has started; when it is popped up, it means that the instrument has
triggered the over-current protection.
8. Voltage adjustment: After turning on the device, you must first turn the knob
counterclockwise to the end, press the start button, and then adjust clockwise to
increase the output high voltage from small to large, and adjust counterclockwise to
reduce the output high voltage from large to small.
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns
off the system power.
10. The fuse holder: the place where the fuse of the AC 220V power supply system is
installed.
11. Power socket: the working power supply of the instrument, AC 220V connection
port.
12. Time setting: Set the discharge time interval.
13. Ammeter: indication of the current on the high voltage side.
14. Voltmeter: high voltage output voltage indicating kV meter.
15. High-voltage output (EMP): When impacting discharge, connect the high-voltage
output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage
output line
Technical parameters
Impact high voltage | 0~15kV |
High voltage partial pressure | 2.5 level |
Built-in capacitor | 8μF |
Discharge power | 0-900J |
Output voltage polarity | negative polarity |
Impact power | 250W @peak |
Working mode | Selectable or adjustable impulse rate and Single shot |
Minimum Output current in DC mode | 16mA at 15kV |
Length of test cable | The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long. |
Over temperature protection | 65ºC |
Over current protection | 8mA (more than 3 seconds) |
Volume(mm) | 540L×300W×450H |
Weight | not more than 25kg |
Power supply | AC220V±15%, 50Hz±2Hz(60Hz) |
Ambient temperature | -20~+60ºC |
Packing List
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Application--Underground cable fault location
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------